 | Network Management | | SNMP Manageable Optional |
 | Interfaces/Ports | | 1 x DB-9 |
 | Status Indicators | | 14 STATUS LEDs offer LINE POWER, ONLINE, BYPASS, ON BATTERY, OVERLOAD, BATTERY LOW, REPLACE BATTERY and FAULT status information. Also includes 4 LED meters for LOAD LEVEL / BATTERY LEVEL display (Battery level readout requires pressing "test" key) |
 | Batteries | | Sealed Lead-acid |
 | Standard Warranty | | 2 Year |
 | Load Capacity | | 3000VA/2400W |
 | Package Contents | | SU3000XL Online, Double-Conversion UPS System PowerAlert Software and cabling Instruction manual with warranty information |
 | Manufacturer | | Tripp Lite |
 | Plug/Connector Type | | NEMA L5-30P |
 | Form Factor | | Tower |
 | Additional Information | | True on-line, double conversion UPS provides pure, sine wave AC output Maintains continuous operation through blackouts, brownouts, voltage fluctuations and surges with zero transfer time Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems Accepts input voltages between 80 and 138 (65 to 138 at loads under 70%), regulating output to 120V AC +/-2% 3000VA / 2400 watt output capacity with 7 total outlets (6 NEMA 5-15/20R, 1 NEMA L5-30R) Two built-in individually switchable load banks can be controlled via the UPS''s software interface to selectively reboot remote equipment or automatically shed less critical loads to extend battery runtime for the most critical equipment (2 banks of 3 outlets) Standard internal battery set provides 17 minutes runtime at half load Expandable runtime with multiple external battery packs (part# BP72V9) Attractive all-black upright tower format DB9 serial network interface supports RS-232 and contact closure messaging Slot for optional SNMP/web card (part# SNMPWEBCARD) Included PowerAlert UPS Power Management Software and cabling provide monitoring of in-depth site power conditions, full UPS status and fault warnings, output load level and load bank power control Compatible with Tripp Lite''s WatchDog Service Monitoring/Rebooting Software (part# WATCHDOGSW) Diagnostic LEDs 2 year manufacturer''s product warranty $250,000 Ultimate Lifetime Insurance (USA & Canada only) |
 | Temperature | | 32 F (0 C) to 104 F (40 C) Operating |
 | Overload Protection | | 2 20A output breakers and 1 40A input breaker |
 | Modular Slots | | 1 x Communications Slot |
 | Backup/Run Time | | 6 Minute 3000VA Full-load 17 Minute 1500VA Half-load |
 | Manufacturer Part Number | | SU3000XL |
 | Battery Life | | 3 Year to 6 Year |
 | Receptacles | | 6 x NEMA 5-20R 1 x NEMA L5-30R |
 | System Requirements | | TYPCICAL APPLICATIONS:Ideal for protection of critical 120V AC servers, networking equipment and sensitive electronics. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems |
 | Humidity | | 0 to 95% Non-condensing Relative Humidity |
 | Manufacturer Website Address | | www.tripplite.com |
 | Alarm | | On Battery Low Battery Overload UPS Fault On Battery |
 | Input Voltage | | 110V AC |
 | Power Cord/Cable | | 10 ft |
 | Input Voltage Range | | 120V AC Single-phase |
 | Battery Recharge Time | | 4 Hour |
 | Dimensions | | 14.75" Height x 5.5" Width x 16.75" Depth |
 | Certifications & Standards | | UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications |
 | Product Line | | SmartOnline |
 | Output Voltage | | 120V AC Single-phase |
 | Shipping Dimensions | | 19.5" Height x 10" Width x 24" Depth |
 | Emergency Power OFF | | Optional |
 | Switching Time | | 0 ms |
 | Frequency | | 60Hz |
 | Weight | | 66 lb |
 | Frequency | | 50Hz |
 | Product Name | | SmartOnline SU3000XL UPS |
 | Shipping Weight | | 73 lb |
 | Product Type | | Dual Conversion Online UPS |
 | Waveform Type | | Sine Wave |
 | Filtering | | EMI / RFI |