Manufacturer: American Power Conversion
Mfg Part#: BE550G
Buy.com Sku: 208050456
UPC: 731304258940
UPC 14: 00731304258940
Buy.com Sales Rank: 590
See more in UPS

Features
| Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance | |
| Resettable circuit breaker: Easy recovery from overloads; no need to replace a fuse. | |
| Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment | |
| Cold-start capable: Provides temporary battery power when the utility power is out. | |
| Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced | |
| Disconnected battery notification: Warns when a battery is not available to provide backup power. | |
| Dataline Surge Protection: Provides protection of connected equipment from power surges on the data lines. | |
| Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced. | |
| Audible alarms: Provides notification of changing utility power and UPS conditions. | |
| User-replaceable batteries: User-replaceable batteries | |
| USB connectivity: Provides management of the UPS via a USB port (not available on all models). | |
| Transformer-block spaced outlets: Transformer-block spaced outlets | |
| Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging. | |
| Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. | |
| Lifetime data recovery warranty: Provides peace of mind by providing professional data recovery services in the event data is lost due to the failure of the unit. | |
| Battery replacement without tools: Allows quick, easy battery replacement. | |
| LED status indicators: Quickly understand unit and power status with visual indicators. | |
| Back-UPS ES Features & Benefits | |
| Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment | |
| Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances. | |
| Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. | |
| Convenience | |
| Audible alarms: Provides notification of changing utility power and UPS conditions. | |
| Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced. | |
| Cold-start capable: Provides temporary battery power when the utility power is out. | |
| Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced | |
| Resettable circuit breakers: Enables a quick recovery from overload events. | |
| Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles. |
Tech Specs
| Output Power Capacity 330 Watts / 550 VA | |
| Max Configurable Power 330 Watts / 550 VA | |
| Nominal Output Voltage 120V | |
| Output Frequency (sync to mains) 47 - 63 Hz | |
| Waveform Type Stepped approximation to a sinewave | |
| Output Connections: | |
| (4) NEMA 5-15R (Battery Backup) | |
| (4) NEMA 5-15R (Surge Protection) | |
| Nominal Input Voltage 120V | |
| Input Frequency 50/60 Hz +/- 3 Hz (auto sensing) | |
| Input Connections NEMA 5-15P | |
| Cord Length 5 feet (1.52 meters) | |
| Input voltage range for main operations 88 - 139V | |
| Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof | |
| Typical recharge time 24 hour(s) | |
| Replacement Battery APCRBC110 | |
| RBC™ Quantity 1 | |
| Interface Port(s) USB | |
| Control panel LED status display with On Line : On Battery : Replace Battery and Building Wiring Fault | |
| Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm | |
| Surge energy rating 340 Joules | |
| Filtering Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 | |
| Data Line Protection RJ-11 Modem/Fax/DSL protection (two wire single line) | |
| Maximum Height 3.40 inches (86 mm) | |
| Maximum Width 7.10 inches (180 mm) | |
| Maximum Depth 11.20 inches (284 mm | |
| Net Weight 12.40 lbs. (5.64 kg) | |
| Shipping Weight 14.40 lbs. (6.55 kg) | |
| Shipping Height 4.96 inches (126 mm) | |
| Shipping Width 8.86 inches (225 mm) | |
| Shipping Depth 15.20 inches (386 mm) | |
| Master Carton Units 2.00 | |
| Master Carton Weight 30.00 lbs. (13.64 kg) | |
| Color Black | |
| SCC Codes 1073130425894 7 | |
| Operating Environment 32 - 104 °F (0 - 40 °C) | |
| Operating Relative Humidity 5 - 95% | |
| Operating Elevation 0-10000 feet (0-3000 meters) | |
| Storage Temperature 5 - 113 °F (-15 - 45 °C) | |
| Storage Relative Humidity 5 - 95% | |
| Storage Elevation 0-50000 feet (0-15000 meters) | |
| Audible noise at 1 meter from surface of unit 45.00 dBA | |
| Online Thermal Dissipation 16.00 BTU/hr | |
| Regulatory Approvals FCC Part 15 Class B,FCC Part 68,NOM,TUV-C,UL 1778,UL 497A,UL 497B | |
| Standard Warranty 3 years repair or replace | |
| Equipment protection policy Lifetime : $75000 | |
| Environmental Compliance RoHS |