 | Package Contents | | SmartOnline 5000 VA Rack-mountable Tower UPS(with SUPDMB56 detachable PDU module)USB, DB9 and EPO cablingRackmount installation kit for 4 post rack enclosuresOwner's manual and warranty information |
 | Batteries | | User-replaceable Hot-swappable |
 | Load Capacity | | 5000VA/3800W |
 | Standard Warranty | | 2 Year(s) |
 | Manufacturer | | Tripp Lite |
 | Network Management | | SNMP Manageable Included |
 | Interfaces/Ports | | 1 x RS-232 1 x USB |
 | Parts Warranty/Labor | | 2 Year(s) |
 | Plug/Connector Type | | NEMA L14-30P |
 | Overload Protection | | Resettable circuit breaker |
 | Form Factor | | 4U Rack-mountable Tower |
 | Additional Information | | Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads.Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 65V (L1-N:L2-N). Below this point, output is maintained utilizing battery reserves.High voltage transfer to battery power: Maintains continuous operation during overvoltages to 140V (L1-N:L2-N). Above this point, output is maintained utilizing battery reserves.Cold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure.Typical Applications: Ideal for protection of sensitive electronics in any application calling for upright tower or 19-inch rackmount UPS protection. Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems.Output frequency regulation: Regulates line frequency to 50/60Hz +/- 0.05Hz |
 | Backup/Run Time | | 8 Minute(s) 5000VA Full-load 22 Minute(s) 2500VA Half-load |
 | Manufacturer Part Number | | SU5000RT4U |
 | Input Voltage | | 110V AC 220V AC |
 | Manufacturer Website Address | | www.tripplite.com |
 | Receptacles | | 8 x NEMA 5-15/20R 2 x NEMA L6-20R 2 x NEMA L6-30R |
 | Input Voltage Range | | 120V AC Split-phase 208V AC Split-phase 240V AC Split-phase |
 | Certifications & Standards | | Tested to UL1778 (USA)CSA (Canada)FCC Class A (Emissions) |
 | Bypass Switch | | Automatic & Manual |
 | Product Series | | SmartOnline |
 | Emergency Power OFF | | Yes |
 | Output Voltage | | 120V AC Split-phase Nominal 208V AC Split-phase Nominal 240V AC Split-phase Nominal |
 | Software Included | | PowerAlert UPS |
 | Frequency | | 60Hz |
 | Product Model | | SU5000RT4U |
 | Switching Time | | 0 ms |
 | Product Name | | SmartOnline 5000 VA Rack-mountable Tower UPS |
 | Voltage Handling | | 3% Output |
 | Current | | 21A |
 | Product Type | | Dual Conversion Online UPS |